Abstract

This research paper handles fabrication and testing issues during localization of a 20-inch cryopump. The developed cryopump is equipped with a two-stage GM (Gifford- McMahon) cryocooler. The GM cryocooler can absorb heat of 80.21 W and 8.05 W at each stage under the temperature of 69.59 K and 17.98 K, respectively. At this time, The electric consumption is recorded to be 5.77 kW. Reliability test on the GM cryocooler is also being conducted to secure track-record in commercializing the developed cryopump (currently 6,500 hours passed). For the cryopump, using nitrogen gas, the ultimate pressure and pumping speed are measured to be 9.07×10SUP-9/SUP mbar and 11,473 L/s.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.