Abstract

The superconducting magnets for the accelerator's rings will be cooled by a forced flow supercritical helium system from a central refrigeration plant. The design temperature for these magnets varies from 2.6 K to 3.8 K depending on a magnets location in the ring. This paper describes the forced flow cooling system for testing a prototype magnet near 2.6 K; this lowest temperature being of special interest to evaluate magnet quench protection. The test forced flow cooling system uses a three-stage approach, including an ejector pumped bath, similar to a cycle described previously. The coolant exists at 3.8 K from these first stages and is then cooled further in a 64 cm diameter by 3 m high shielded liquid helium dewar. The supercritical helium gas passes through a submerged copper coil in this bath which is pumped to a pressure of 65 mm absolute by a screw compressor system. Temperatures are measured by thermistors located in the gas stream, and also embedded in the magnet coil.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.