Abstract
Exposure biomarkers are required in tobacco use studies to accurately assess smoking status since self-reporting usually results in misclassification estimates. This study uses breath analysis and assesses some volatile organic compounds (VOCs) as potential biomarkers of tobacco smoke exposure. Forced-expiratory breath samples were obtained from 377 volunteers (174 smokers and 203 nonsmokers). Exhaled breath levels of different VOCs previously related to tobacco smoke were evaluated. The toluene-to-benzene ratio was evaluated as this ratio has been found to be different in atmospheric samples and tobacco smoke emissions. Finally, breath analyses from 64 patients attending a clinical practice were evaluated and the results were compared to their self-reporting status. Univariate analysis shows that all compounds evaluated gave significant differences (p < .001). Receiver operating characteristic (ROC) curves suggest that xylenes and toluene are not able to accurately determine smoking status, and benzene and the T/B ratio present potential utility in certain conditions. The highest discriminant capacity was obtained for 2,5-dimethylfuran (AUC = 0.982, 95% confidence interval [CI]: 0.969-0.995), with a cut-off value of 0.016 ppbv (sensibility = 0.965, specificity = 0.896). Drinking coffee was the only confounding parameter that can give low breath levels for this compound. The evaluation of the results obtained from the patients attending a clinical practice showed that 8% of people who claim to be nonsmokers hid their real smoking status. The results obtained confirm that the determination of 2,5-dimethylfuran in breath samples is a good and simpler alternative to conventional blood or urine tests for assessing smoking status. Analysis of 2,5-dimethylfuran in breath samples results in a simple and fast method for the determination of the smoking status of a person. This methodology presents multiple advantages as it is neither invasive nor embarrassing for patients attending clinical practices. Moreover, analysis of biomarkers in breath samples is simpler and faster than using conventional methods based on urine or blood analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.