Abstract
Positron emission tomography (PET) as the functional component of current hybrid imaging (like PET/ CT or PET/MRI) seems to dominate the horizon of medical imaging in coming decades. 18Flourodeoxyglucose (18FDG) is the most commonly used probe in oncology and also in cardiology and neurology around the globe. However, the major capital cost and exorbitant running expenditure of low to medium energy cyclotrons (about 20 MeV) and radiochemistry units are the seminal reasons of low number of cyclotrons but mushroom growth pattern of PET scanners. This fact and longer half-life of 18F (110 minutes) have paved the path of a centralized model in which 18FDG is produced by commercial PET radiopharmacies and the finished product (multi-dose vial with tungsten shielding) is dispensed to customers having only PET scanners. This indeed reduced the cost but has limitations of dependence upon timely arrival of daily shipments as delay caused by any reason results in cancellation or rescheduling of the PET procedures. In recent years, industry and academia have taken a step forward by producing low energy, table top cyclotrons with compact and automated radiochemistry units (Lab- on-Chip). This decentralized strategy enables the users to produce on-demand doses of PET probe themselves at reasonably low cost using an automated and user-friendly technology. This technological development would indeed provide a real impetus to the availability of complete set up of PET based molecular imaging at an affordable cost to the developing countries.
Highlights
The major capital cost and exorbitant running expenditure of low to medium energy cyclotrons and radiochemistry units are the seminal reasons of low number of cyclotrons but mushroom growth pattern of Positron emission tomography (PET) scanners
This fact and longer half-life of 18F (110 minutes) have paved the path of a centralized model in which 18FDG is produced by commercial PET radiopharmacies and the finished product is dispensed to customers having only PET scanners
Positron emission tomography (PET) has become the hallmark of nuclear medicine attributed to its high sensitivity, better spatial resolution and absolute quantification
Summary
Positron emission tomography (PET) has become the hallmark of nuclear medicine attributed to its high sensitivity, better spatial resolution and absolute quantification. This fact and longer half-life of 18F (110 minutes) have paved the path of a centralized model in which 18FDG is produced by commercial PET radiopharmacies and the finished product (multi-dose vial with tungsten shielding) is dispensed to customers having only PET scanners.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.