Abstract
In the only study to measure dynamic pulmonary compliance (C) in cystic fibrosis infants (CFI) it was low. Esophageal catheters were used, but these are invasive and may be inaccurate due to chest wall distortion. We evaluated weighted spirometry technique for measuring total respiratory system compliance (Crs) in CFI. We studied during sleep 5 CFI and 9 normal controls (NC) mean ages 6.1 and 6.2 months. We tested respiratory rate (RR), functional residual capacity (FRC) by helium dilution, mixing index (MI), specific total respiratory system compliance, Crs'=Crs/FRC, and size corrected flows (VmaxFRC/FRC) by rapid chest compression.CFI had lower Crs' than NC but similar flows. In the absence of small airways dysfunction, the low Crs' and higher RR in CFI could result from increased elastic recoil since Crs' should be quasi static after equilibration of pressure to all lung units. However, the low MI and high FRC in CFI indicates small airway dysfunction. Thus, the low Crs may be secondary to frequency dependence. We conclude that Crs is low in CFI and represents a non-invasive method for assessing early pulmonary dysfunction. Supported by NIH Grant #HL01322-01, HL990-03 and ALA Fellowship.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.