Abstract

Ultra precision apparatus like semiconductor producing equipment needs the high accuracy at manufacturing. Therefore active isolation systems to avoid vibration transmitted from a vibration source to the precision apparatus are very important If elastic loads are put on the isolation table, vibration modes of the table are changed and the isolation performance is degraded. Therefore, the controllers for the active isolation table should be designed taking account of elastic loads For this purpose, a dynamical model must be identified that takes the dynamics of elastic loads into consideration to such controllers. In this research, an experimental active isolation table with an elastic load is built Its dynamical model is identified and a feedback controller is designed by using the model Property of the obtained controller is qualified through computer simulations

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.