Abstract

Background Assessment of hyperaemia during adenosine stress CMR remains a clinical challenge with lack of a gold standard marker of adequate stress. Multiple parameters including the splenic switch off (SSO) sign, heart rate response (HRR) and blood pressure response (BPR) are used in clinical practice. Perfusion mapping provides a pixelwise representation of myocardial blood flow (MBF), allowing for measurement of MBF at a regional level. This may provide an alternative tool for assessment of hyperaemia. Objectives To validate the use of stress MBF for assessment of hyperaemic response and compare this to currently used clinical markers. Methods In total, 216 subjects were recruited. This included 3 cohorts: 1) Derivation cohort (22 healthy volunteers) to identify a stress MBF threshold value representative of the normal minimum response to adenosine; 2) Validation cohort (37 patients with suspected coronary disease) who underwent stress CMR and invasive coronary physiological assessment on the same day, to validate the stress MBF threshold value against invasive markers of hyperaemia; 3) Clinical cohort (159 patients undergoing clinically-indicated adenosine stress CMR) to assess the presence of stress MBF-defined hyperaemia and other physiological markers of hyperaemia (SSO, HHR and BPR). Results From the derivation cohort, maximum stress MBF (SMBFmax) >1.43 ml/g/min was derived as the threshold value of hyperaemia (defined as 1.96 standard deviations below the sample mean of lowest stress MBF values). This threshold was tested in the validation cohort: 100% of patients with invasive evidence of hyperaemia demonstrated SMBFmax >1.43 ml/g/min, 81% had SSO and 81% had HRR >10 bpm. Of the clinical cohort, 93% had hyperaemia defined by SMBFmax compared to 71% using SSO and 81% using HRR. SMBFmax was no different in those with or without SSO (2.58±0.89 ml/g/min vs 2.54±1.04 ml/g/min, p=0.84) but those with HRR had significantly higher SMBFmax (2.69 ml/g/min vs 1.95 ml/g/min, p HRR >16 bpm was able to predict SMBFmax >1.43 ml/g/min with sensitivity 63% and specificity 91% (AUC 0.87, p Conclusion Adenosine-induced increase in MBF measured using perfusion mapping is accurate for the confirmation of hyperaemia during stress CMR studies and is superior to traditional, clinically used markers of adequate stress.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.