A self-retaining Dingman mouth retractor is widely used to keep the mouth open during cleft palate and intraoral surgery. The airway is at risk of being crushed or occluded as the gag (tongue plate) of the Dingman mouth retractor is being pushed against the endotracheal tube.Kinking of the endotracheal tube between the teeth and Dingman mouth retractor has been reported even with the oral Ring-Adair-Elwyn or flexometallic or armored endotracheal tubes. To minimize kinking of the endotracheal tube and its consequent complications, we routinely insert an 18-gauge needle cap at the potential space between the teeth and the tongue plate (gag) of the Dingman mouth retractor, which is situated lateral to the endotracheal tube. In our experience of approximately 5000 intraoral cases using a Dingman mouth retractor and 18-gauge needle cap, we have not had any tooth avulsion or aspiration of the 18-gauge foreign body while maintaining a consistent and secured airway during cleft palate and intraoral surgery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.