Abstract

AIMS To test the hypothesis that the improved resolution afforded by 16-detector computed tomography (CT) would translate to better stress fracture detection when compared with skeletal scintigraphy. MATERIALS AND METHODS Thirty-three cases of suspected stress fractures in 26 patients were investigated using skeletal scintigraphy and 16-detector CT performed on the same day. Planar images of the lower limbs were taken 3h post-injection of 400MBq 99m Tc-methylene diphosphonate ( 99m Tc-MDP). 99m Tc-MDP uptake was quantified at suspected fracture sites. CT was performed using a 16-detector multisection machine employing 0.75mm detectors and images reconstructed in 0.5mm increments. Examinations were reported independently and discordant results were compared at follow-up. RESULTS At initial reporting scintigraphy identified fractures in 13 of the 33 cases and CT identified four of the 33. In one case, on review of the CT images, a fracture was present in the distal fibula that was not initially identified. This resulted in eight scintigraphic-positive CT-negative discordant cases. The 99m Tc-MDP uptake was significantly lower in the discordant fracture group compared with the concordant group ( p CONCLUSIONS Despite technological advances in CT, scintigraphy appeared to detect more stress fractures. As such, multidetector CT should not be used as a routine initial investigation in stress fracture detection. The potential use of 99m Tc-MDP quantification at fracture sites is of interest and may be worth further investigation.