Abstract
Pulmonary vein ablation (PVA) has been used to treat persistent supraventricular arrhythmias, in which a cardiologist first isolates and then thermally ablates the source of the arrhythmia1. Since the esophagus is in close proximity to the left atrium, heat induced injury to the esophagus may occur2. Although the incidence is low, the mortality rate is high. Luminal esophageal temperature (ET) monitoring is one of the most effective measures to minimize the risk of injury3. In this retrospective study, we elected to analyze temperature changes during PVA at two different temperature monitoring sites in the esophagus. The anesthetic technique was standardized and utilized general anesthesia, endotracheal intubation and an arterial line. ET monitors were placed at two mid-atrial locations, ET1 and ET2 separated by 1–1.5 inches in the esophagus, as determined by cardiologist using fluoroscopy. Temperatures at both ET1 and ET2 locations were recorded simultaneously when radio-frequency ablation was performed at different left atrial sites. The peak ET was recorded at each location. In particular, the increase over baseline ET and the difference between ET1 and ET2, were noted. Twenty five patients were studied. Ablation sites in the left atrium included the anterior, posterior, inferior regions and the pulmonary veins. The most significant increases in temperature were seen during ablation of the posterior left atrium ranging from 0.1 to 4.0 degrees. However, in 20 out of 25 patients, measurements of ET1 ≠ ET2. The absolute value of difference of temperature between ET1 and ET2 ranged from 0.4 to 3.8, with a mean of 1.3 and a standard deviation of 1.1. These findings suggest that measurement of temperature at two separate esophageal locations is more sensitive that one location in detecting temperature increases during PVA. The ablating electrode during PVA moves from different areas within the left atrium, and therefore, a wide area of temperature measurement is needed for more accurate monitoring. Furthermore, the most significant increases in temperature occurred when ablation performed in the posterior left atrium, adjacent to the esophagus. The implications of these observations suggest that one location of temperature measurement may not be accurate enough in detecting a “true” esophageal temperature. Further studies are needed to verify these findings in a prospective study and to ascertain whether this has any patient safety ramifications for preventing esophageal injury.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.