Abstract

A high order Digital Image Correlation Method (DCM) was developed to measure a strain distribution at notch root with a high accuracy. Only a uniform deformation in a subset was considered in the conventional DCM system. However, the strain distribution near the stress concentrated area, like a notch, was not complex. For the application was incorporated into the conventional DCM system. From the measurement result, the developed DCM system was found to be effective to measure the strain in the vicinity of notch root.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.