During follow-up of thyroid cancer, 131I whole-body scan showed intense tracer uptake in the right hemithorax of a patient previously submitted to thyroidectomy and radioiodine therapy for differentiated thyroid cancer. Thyroglobulin was undetectable at the time of the scan. Single-photon emission computed tomography/computed tomography (SPECT/CT) of the thorax correctly identified widespread bronchiectasis 131I-avid in the middle lobe of the right lung. After bronchoalveolar lavage, a bronchial specimen was positive for Mycobacterium avium infection. Hybrid imaging with SPECT/CT allowed to correctly identify a false-positive case of 131I uptake due to inflammation in a single diagnostic session, minimizing patient discomfort or misdiagnoses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.