Abstract

Use of interstitial radiation holds promise in the treatment of primary malignant brain tumors, but optimal technical factors have yet to be determined. We have developed a method of precise CT directed stereotactic placement of radioactive sources in a predetermined target volume. We use low activity (1–2 millicurie/seed) sources of 125I loaded in silastic catheters, which are positioned in a parallel array in the target. Positioning of such multiple sources toward the periphery of the volume enhances achievable dose homogeneity. Seeds of various activities can be differentially loaded into each catheter and the catheters can be positioned at various radii from the central target so that the treated volume corresponds to the identified (often irregular) target volume. Although the implant is designed to be permanent, the sources can be removed easily in a second procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.