Abstract

Intraoperative gamma probe guidance has become widely utilized for sentinel lymph node dissection in patients with breast cancer and melanoma, using (99m)Tc sulfur colloid. However, new indications are possible and need to continue to be investigated. We report the use during a wedge liver biopsy of a new hand-held gamma probe designed for (123)I intraoperative guidance. The patient studied is a 5-year-old boy with history of stage 4 high-risk neuroblastoma. Anatomic imaging (CT, MRI), (99m)Tc bone scintigraphy and 2-deoxy-2-[F-18]fluoro-d-glucose-positron emission tomography/computed tomography (FDG-PET/CT) were negative, but the (123)I MIBG scintigraphy suggested recurrent liver disease. A decision was made to biopsy these lesions to obtain histopathological confirmation. Intraoperative gamma probe mapping of the liver identified areas with signal above the background, but these were prove to be hemosiderin deposits on histo-pathology examination.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.