Abstract

123I-metaiodobenzylguanidine cardiac scintigraphy (MIBG) is a useful imaging technique for the diagnosis of dementia with Lewy bodies (DLB). However, MIBG has a serious disadvantage in that it demands a long examination time. The objective of this study was to evaluate statistically the usefulness of the heart/mediastinum ratio (H/M) from the early phase of MIBG for the differential diagnosis of DLB. In total, 113 patients were examined, including 32 non-DLB (19 with Alzheimer's dementia) and 79 DLB patients. The mean early-H/M ratio was 2.83 in the non-DLB group and 1.95 in the DLB group. The mean delayed-H/M ratio was 3.0 in the non-DLB group and 1.76 in the DLB group. With a cutoff point of 2.27 on early images, the sensitivity, specificity, and diagnostic accuracy were 65%, 94%, and 73%, respectively, and the area under the curve was 0.82, indicating moderate accuracy. This analysis indicates that images from the early phase of MIBG alone are sufficient for the differential diagnosis of Alzheimer's disease and DLB.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.