Abstract

The aim of this study was to investigate the 12-month flexural mechanical properties of 23 flowable resin-based composites (FRBC) that included 5 self-adhesive FRBC materials. Specimens were evaluated following ISO 4049:2019 guidelines, but additionally stored in physiologic 0.2M phosphate buffered saline solution being tested at 24 h, 1 week, 1 month, and at 3-, 6-, 9-, and 12-months. While some deviation and degradation were noted at testing intervals, conventional FRBC materials overall demonstrated greater flexural strength than the self-adhesive and compomer materials. Three self-adhesive materials and the compomer were below recommended ISO 4049:2019 flexural strength values at 24 h with another after 6 months storage. Conventional FRBC materials, except at 1 month, overall demonstrated increased flexural modulus than the self-adhesive FRBC materials. Although results were material dependent, conventional FRBC materials demonstrated overall greater flexural mechanical properties as compared to the self-adhesive FRBC materials and the compomer evaluated.