A reduction system of seismic response for small structure that was installed inside buildings was developed using friction bearings. In this paper, effects of bearing combination on reduction were investigated by vibration test. The best combination of bearing is case 2 that was used two marble plates and two steel balls with rubber pad, and the maximum response amplitude decreases 80% compared to input wave. On the other hand, in case 1 that was used four steel balls, it amplified because of resonance between input wave and isolated plate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.