Abstract

Three experiments were designed to evaluate the effect of the length of insertion of a intravaginal progesterone (P4) device on follicular and corpus luteum (CL) diameter, time of ovulation, and pregnancy rates following fixed-time AI (P/FTAI) in Bos indicus cows treated with an oestradiol/P4-based treatment with a lengthened proestrus, named J-Synch. Multiparous suckled Bos indicus beef cows that were 35 to 60 days postpartum were used in Experiments 1 and 2, whereas non-lactating cows were used in Experiment 3. All cows had a CL or a follicle of at least 8mm in diameter and a body condition score between 2.5 and 4 (1 to 5 scale) at the time of treatment. On Day 0, all cows received 2mg of oestradiol benzoate (EB; Sincrodiol, Ourofino, Brazil) and a previously used intravaginal device (1g of P4; Sincrogest, Ourofino). The P4 device was removed on Day 6 in the J-Synch 6-day group and on Day 7 in the J-Synch 7-day and Control groups. All cows received 500µg of cloprostenol (Sincrocio, Ourofino) and 400IU of equine chorionic gonadotrophin (SincroeCG, Ourofino) at the time of P4 device removal, and cows in the Control group also received 0.5mg of oestradiol cypionate (ECP, SincroCP, Ourofino) at the same time. In Experiment 1, cows (n=20 per group) were examined every 12h, from P4 device removal to determine the time of ovulation and 7 days after ovulation to measure the CL. In Experiment 2, all cows (n=200 per group) were tail-painted for oestrous detection. Cows with=50% of the tail-paint rubbed-off by 72h (J-Synch groups) or 48h (Control group) after P4 device removal, were FTAI at that time. Cows not designated as showing oestrus at that time received 10µg Buserelin (GnRH, Sincroforte, Ourofino) and were FTAI 8h later. In Experiment 3, P/FTAI was compared in cows that received the J-Synch 7-day treatment (n=265) or the 7-day Control treatment (n=250). Data were analysed using the GLM mixed procedure (InfoStat). In Experiment 1, the diameter of the ovulatory follicle was larger (P<0.05) and the interval to ovulation was longer (P<0.05) in the J-Synch groups (J-Synch 7 d: 16.4±0.2mm and 86.0±3.0 h; J-Synch 6 d:15.5±0.3mm and 83.0±4.0h) than in the Control group (13.8±0.2mm and 64.0±3.0h). Furthermore, CL diameter was greater (P<0.05) in the J-Synch 7-day group (21.9±0.8mm) than in the J-Synch 6-day (18.7±0.8mm) and Control (16.8±0.9mm) groups. In Experiment 2, P/FTAI was higher (P<0.05) in the J-Synch 7-day group (116/200; 58.0%) than in the J-Synch 6-day (93/200; 46.5%) and Control (98/200; 49.0%) groups. In Experiment 3, P/FTAI was higher (P<0.05) in the J-Synch 7-day group (161/265; 60.7%) than in the Control group (124/250; 49.6%). In conclusion, delaying the removal of the P4 device by 1 day (i.e. Day 7 vs. Day 6) in the J-Synch protocol and lengthening the proestrous period (i.e. J-Synch 7-day vs. 7-day Control) resulted in higher P/FTAI in Bos indicus cows.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call