Abstract
Introduction CT coronary angiography (CTCA) is widely applied in coronary artery disease. It is therefore important that imaging protocols are optimised to obtain diagnostic images at the lowest possible radiation dose. We aimed to establish the feasibility of single heart-beat imaging in 320-multidetector CTCA, and assess variables that affect image quality. Methods Consecutive patients (n=249, 38% male) underwent contrast enhanced prospective electrocardiogram-gated single heart-beat CTCA. We assessed images before and after the introduction of sublingual glyceryl trinitrate to the CTCA protocol. Tube current and voltage were selected based on body-mass index (BMI) and acquisition window was selected based on heart rate (70–80% or 30–80% if the heart rate was below or above 65 beats/min respectively). Images were assessed by two trained observers and image quality was graded on a 4-point scale (1, excellent; 4, poor). Obstructive disease was defined as a stenosis of greater than 70% diameter. Results The mean heart rate was 60 beats/min (95% CI 59 to 62), BMI 29 kg/m 2 (28, 30), age 58 years (56, 59) and dose-length product 283 mGy cm (266, 301). During scanning, 133(51%) received sublingual glyceryl trinitrate (GTN), 9(4%) had ectopic beats, and 12(5%) had atrial fibrillation. Diagnostic image quality was obtained in 99% with mean image quality 1.4 (1.3, 1.5). For patients with a BMI of 30 or above (n=111) diagnostic image quality was obtained in 109 scans (98%) and excellent image quality was obtained in 78 scans (70%). For patients with a heart rate above 65 bpm (n=58) diagnostic image quality was obtained in 98% (57 scans) and excellent image quality was obtained in 36% (21 scans). The mean dose-length product was 283 mGy cm (266, 301). An increase in heart rate led to an increase in radiation dose to 377 mGy cm (286, 268) for patients with a heart rate of greater than 80 beats/min (p Conclusions Optimal image quality in single heart-beat 320-multidetector CTCA is achievable at low radiation doses in 99% of unselected patients. Image quality is further improved by lower heart rate and sublingual GTN. This study has established the use of half-segment reconstruction in all patients undergoing wide volume CTCA irrespective of heart rate, ectopic beats and the presence of atrial fibrillation. A widened window of acquisition can be used to improve image quality in patients with a heart rate greater than 65 beats per minute. In addition we have established that the use of GTN improves image quality in 320 multidetector CTCA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.