Abstract

<h3>Background</h3> In optimisation of CRT (and even selection for implantation) we may have underestimated the impact of beat-to-beat variation on echocardiographic measurements. This can be quantified most clearly in the optimisation process, in which genuine small changes in cardiac function (signal) must be detected among potentially large beat-to-beat variation (noise). <h3>Methods and Results</h3> In this large study of biological variability, we performed over 2000 echocardigraphic measurements in 12 patients. We performed separate, replicate measurements at a series of interventricular delays of each potential optimisation modality at rest. This included (i) 3D systolic dyssynchrony index, (ii) aortic pre-ejection time, (iii) interventricular mechanical delay, (iv) LVOT VTI and (v) QRS width. The equivalent of 31 optimisations per patient were performed. For single measurements at each setting, agreement between successive optimisations was low, at 39% for SDI, 41% for aortic pre-ejection time, 32% for IVMD, 54% for LVOT VTI and 58% for QRS width. Agreement between one method and another, using single replicates, was similarly low, with the average agreement between optima by two methods being only 18% similar to pure guesswork. The intraclass correlation coefficient was low for all methods at 0.11, 0.51, 0.30, 0.50 and 0.55 respectively. The intraclass correlation coefficients improved to 0.19, 0.63, 0.42, 0.54 and 0.66 (p=0.001) when averages of paired measurements were used. To optimise within 20 ms or 10 ms of the true optimum, requires a greater number of measurements, as seen in Abstract 116 figure 1, dependant on the intraclass correlation coefficient. The scatter of optima obtained reduced (improved) significantly when using averaged pairs of measurements compared to single measurements from 23 ms to 18 ms (3D SDI), 14 ms to 10 ms (aortic pre-ejection time), 28 ms to 22 ms (IVMD), 21 ms to 16 ms (LVOT VTI) and 14 ms to 10 ms QRS duration (p=0.0002). <h3>Conclusions</h3> Because of beat-to-beat variability, VV delay optimisation by any of the echocardiographic techniques is not realistic unless multiple replicates are performed and averaged. Smoothing biological variation by averaging multiple measurements allows the full potential of echocardiographic optimisation to be achieved and improves the consistency of optimisation. Trying to save time by performing inadequate numbers of replicates is a false economy and leads to optimisation being a form of randomisation. These observations may also cast light on to why attempts to identify future responders from CRT has not – when tested in externally monitored randomised trials—been fruitful: dyssynchrony assessment to select patients for implantation may need averaging too, and of far more replicate measurements than is current practice. Integration of this biological insight into technological achievements of clinical imaging is necessary, if reliable predictors of which patients will benefit from CRT, are to be developed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call