Abstract

In the present study, we try to reveal the instantaneous and three-dimensional flow structures in the suction sumps, because the strong unsteadiness and three-dimensionality of such flow. Specifically, we conduct consecutive flow-velocity measurements in a suction sump both by a three-dimensional particle tracking velocimetry (referred to as 3D-PTV) and an ultrasonic velocity profiler (UVP), assisting each other. As a result, we have confirmed a good agreement on time-mean three-dimensional velocity distributions between the 3D-PTV and the UVP. In addition, we reveal some typical flow fields in the sump by the 3D-PTV, and discuss the relationship between flow patterns and the air entrainment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.