Abstract
The natural cooling capability and flow field in relatively small electronic equipment were studied. A vertical channel model was used as an experimental model of electronic equipment. The channel model has two vertical copper walls modeling the printed circuit boards and two transparent walls modeling the casing walls. The clearance between the copper walls is varied from 5 mm to 15 mm. The natural cooling capability was obtained as functions of the wall clearance. The velocity profiles in the channel were quantitatively measured using a particle image velocimetry (PIV). When the channel clearance was 5 mm, the cooling capability of the natural convection was dropped and the velocity in the channel model was reduced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.