The steam generator (SG) in a pressurized water reactor (PWR) is an important component as boundary between the primary loop and the secondary loop. In this study, we performed two-phase flow analysis of SG reliability tests conducted by the Nuclear Power Engineering Corporation (NUPEC) using the two-fluid models of a thermal-hydraulic computer code PHOENICS. It was difficult to calculate the location of the boiling initiation accurately because the location was greatly affected by the friction coefficients (i.e. velocity distributions) and the heat transfer distributions. However, the friction coefficients and the heat transfer distributions did not greatly affect the void fractions in the upper region of the U-bent tubes and the calculated average void fractions agreed with the measured within 4%.Copyright © 2002 by ASME

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.