Abstract

Differential pressure transmitters with an orifice are widely used as a reliable flowmeter in process industries. The most frequent problem with this type of flowmeter is blockage in impulse line: it causes a severe deterioration of measurement accuracy. Hence, this paper develops a new detection method of impulse line blockage with digital differential pressure transmitter in a steady-state steam line. This method, which utilizes inherent pressure fluctuations of the steam line, consists of two functions: (i) detecting impulse line blockage by evaluating standard deviations of differential pressure, and (ii) specifying which side of impulse line is blocked from the phase difference between two impulse lines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.