Abstract

The counter-rotating approach on wind turbine has been recently put in interest for its certain advantages in both design and performance. This paper introduces a study on a counter-rotating wind turbine designed and modeled using NREL airfoils S822 and S823. The aims of the study is to evaluate and discover the performance of the counter-rotating system, and compares to that of single rotor turbine of same design using numerical simulation. The results show higher performance of the counter-rotating system compared with single rotor case at TSR 3 to 5 but lower performance at higher TSR. This is due to the interaction between upstream and downstream rotors. Thus, the counter-rotating turbine is more efficient at low rotor rotational speed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.