Abstract
We measured the magnetic flux desities and the magnetization curves on neutron irradiated fast reactor grade type 316 stainless steels by a flux gate sensor and a newly developed vibrating sample magnetometer, respectively. As the result, it was revealed that there is a good relationship between magnetic property and dose, one of representative irradiation damage parameters. This result shows the possibility of nondestructive evaluation of neutron irradiation damage based on magnetic properties.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.