Abstract

<h3>Background</h3> Around 1 in 100 neonates are born requiring extensive resuscitation, including intubation.<sup>1</sup> Neonatal intubation is traditionally taught using direct laryngoscopy (DL), and the RCPCH paediatric curriculum emphasises that trainees should be capable of bag/mask ventilating and endotracheal intubation of a neonate. In anaesthetic practise it is encouraged to plan for failure and consider alternate laryngoscopy methods if initial intubation is unsuccessful. Video laryngoscopy (VL) may allow faster time to best view and better views compared to direct laryngoscopy (DL) during intubation of the anatomically normal neonate.<sup>2</sup> Furthermore, VL can be effective for training purposes allowing real time feedback from senior colleagues and quicker acquisition of intubation skills.<sup>3</sup> <h3>Objectives</h3> The primary objective is to educate paediatricians to use VL. The secondary objective is to assess change in opinions and confidence in VL following simulation training. <h3>Methods</h3> Within a district general hospital, 17 participants including 12 paediatric trainees and 5 non-trainee participants (consultants, physicians associates and medical students). Each participant completed a pre and post simulation questionnaire, which included assessment of prior VL education and experience, understanding of planning for failure and confidence in VL technique. Low fidelity simulation training of VL (MacGrath) and airway adjuncts was undertaken by paediatric and anaesthetic colleagues. <h3>Results</h3> Of the participants, 8/17 (47%), including only 3/12 (25%) of the trainee group, had received previous training in VL, and 5/17 (29.4%) had previously used VL during real time intubation. In the pre-education group, 4/17 (23.5%) preferred initial intubation attempts using VL, which increased in post education group to 8/17 (47%). In the pre-education group, 6/17 (35.2%) stated they would choose VL for second intubation attempt, which increased in the post-education group to 15/17 (88.2%). In the pre-education group 4/18 (23.5%) stated they would be confident in using VL for second intubation attempt, which increased to 13/17 (76.4%) in the post-education group. <h3>Conclusions</h3> VL is a beneficial tool for neonatal intubation and non-invasive surfactant administration, and is a useful for allowing real-time feedback on the procedural skills from a supervising senior. In our study, we demonstrated that VL training and experience wasn’t extensive, and following a short education programme, confidence and enthusiasm for VL increased. <h3>References</h3> Lingappan K, Arnold JL, Fernandes CJ, Pammi M, et al. Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in neonates. <i>Cochrane Library</i> 2018:CD009975–CD009975. Fiadjoe JE, Gurnaney H, Dalesio N, Sussman E, et al. A Prospective Randomized Equivalence Trial of the GlideScope Cobalt® Video Laryngoscope to Traditional Direct Laryngoscopy in Neonates and Infants. Anesthesiology 2012;116:622–8. O’Shea JE, Thio M, Kamlin CO, McGrory L, et al. Videolaryngoscopy to Teach Neonatal Intubation: A Randomized Trial. Pediatrics 2015;136:912–9.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.