Abstract

Giga-cycle fatigue tests were conducted for heats B and C of SUP 7 spring steels tempered at 430 and 500°C. Rotating bending, electromagnetic, high-speed servohydraulic and ultrasonic fatigue testing machines were used at 30 or 100 Hz, 120 Hz, 600 or 800 Hz and 20 kHz, respectively. The heat B developed fish-eye fractures only with an origin of an Al2O3 inclusion, while Al2O3 and TiN inclusions and matrix cracks appeared at the origins in case of the heat C. The Al2O3 inclusions in the heat B were larger than those in the heat C. Hence, the heat C revealed higher fatigue limit than the heat B. In case of fish-eye fracture, S-N curves under 100 Hz rotating bending, and 600 or 800 Hz and 20 kHz uniaxial loading were coincident each other in both heats, while those under 120 Hz uniaxial loading were lower. The frequency effects were negligible in case of fish-eye fracture and the difference between 120 Hz uniaxial tests and others were explained by the difference of the control volumes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.