Abstract

Alumina fiber reinforced alumina with the SiC interlayer was developed. The composite can heal the delimitation of the fiber/matrix interface by using the high temperature oxidation of the SiC interlayer. Healing at 1300 ℃, corresponding to the optimal self-healing temperature of SiC particles dispersing self-healing ceramics, gives rise to the large strength recovery as well as the alumina fiber degradation. Thus, the composite healed at 1300 ℃ was lost the large deformation ability. On the other hand, it was found that healing at 1000 ℃ for 100 h can lead to the complete strength recovery without alumina fiber degradation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.