Abstract
The cause of pressure fluctuation occurred in a multi-stage centrifugal blower with inlet guide vane (IGV) under the partially opening condition of IGV was investigated using the system dynamics calculation based on the lumped parameter model. This pressure fluctuation occurred in the flowrate region where the slope of total static pressure-rise characteristic curve was steeply negative and total system seemed to be stable, hi our previous study, this pressure fluctuation was considered to be the mild surge that was caused by the stability balance between the first stage and the second to last stage. The system dynamics calculations could reproduce the mild surge behavior in the system and we confirmed that this pressure fluctuation was certainly the mild surge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of the Fluids engineering conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.