Abstract

This report presents an evaluation of the Thermal Storage subsystem at Solar One, the 10 MW/sub e/ Solar Central Receiver Pilot Plant near Daggett, California. The Thermal Storage Subsystem has an availability of around 90%, a first law thermal efficiency of 83%, and can achieve its design discharge capability of 7 MW/sub e/ (net) for four hours. The heat transfer oil mass loss due to thermal decomposition at its elevated temperature is between 5 and 7% of the oil inventory per year - a loss within the range predicted by laboratory experiments. The Thermal Storage Unit tank wall stresses appear to have risen slightly; however, inaccuracy of the strain gages makes conclusive statements impossible. Heat exchanger leaks appeared in the flange seals and the tube-to-tubesheet rolled joints of the charging heat exchangers. Repairs were successful on the flange joint seals, but were unsuccessful on the tube-to-tubesheet seals. Overall, the Thermal Storage Subsystem has functioned well and has met design specifications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.