Abstract

ABSTRACTExperimental investigation on the concrete‐filled tubular gusset plate T–connections is presented in this paper. Three different loading conditions, including axial tension, eccentric tension and in‐plane bending, were applied to the brace of connection. The chord wall slenderness ratio (D/t) of the test specimens ranged from 48 to 75. Each connection was tested to failure, and the behavior under loading was recorded. Punching shear failure of the chord member was the main failure mode observed during the tests. It is recommended that the contribution of concrete be considered in the design because it could effectively restrain the deformation of the chord wall that was observed in the test. The proposed design equations predict the ultimate strengths of the concrete‐filled tubular gusset plate T–connections generally well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.