Abstract

A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66m in width, 0.5m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. The amplitudes of the vibration are measured under the different gate opening and water level conditions in flow from the gate outside to the gate inside. Also 5 revised gate models with bottom width increased 0.5 cm each are tested under the different gate opening and water level. The results are analyzed to study the characteristics of the gate vibration. These test results are assessed in comparison with formerly test results, as a result, presents a design method of Tainter gate to reduce the gate vibration and a basic data for the guide manuals of gate management.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.