Abstract

A chromel-alumel thermoelectric flow sensor using thermal isolation membrane was fabricated. Temperature coefficient of resistance of thin film Pt-heater was about , and Seebeck coefficient of chromel-alumel thermocouple was about . The sensor showed that thermoelectric voltage decreased as thermal conductivity of gas increased, and -flow sensitivity increased as heater voltage increased or the distance between heater and thermocouple decreased. When heater voltage was about 2.5 V, -flow sensitivity and thermal response time of the sensor were about and 0.18 sec., respectively. Linear range in flow sensitivity of the flow sensor was wider than that of Bi-Sb flow sensor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.