Experiments on γ-ray leakage through a slit in lead shield were conducted as part of mock-up tests for shielding to be provided on the first Japanese nuclear propelled ship. The dry shielding test facility in JRR-4 was utilized for the experiments.Experimental results are reported for straight slits, with data covering γ-ray leakage as function of slit width, beam incident angle and of positions of measurement. A semi-empirical method is proposed for estimating the dose rate distribution of the streaming component.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.