Abstract

Objective: To evaluate the diagnostic accuracy of different beta-human chorionic gonadotrophin (ß-hCG) levels measurement, for predicting success of medical treatment in cases diagnosed as tubal ectopic pregnancy (TEP).Design: Five-year prospective observational study.Setting: Prenatal Diagnosis Unit, Vall d'Hebron University Hospital – Barcelona.Patients: TEP cases fulfilling criteria for medical treatment with Methotrexate.Interventions: ß-hCG levels were measured on d 0, 4 and 7 of treatment. Results were compared by non-parametrical tests. A ROC curve was plotted to define cut-off points. Diagnostic accuracy of the different measurements was evaluated.Main outcome measure: Failure of treatment defined as need for surgical treatment or persistence of high ß-HCG levels despite treatment.Results: 126 women were diagnosed as TEP, eligible for medical treatment. There were no differences in parity, age, previous TEP, or adnexal mass size. Success rate was 88%. ß-HCG decreased significantly more, between days 0–7 and 4–7, in the successful cases. LR for success prediction was 6.2 and 7.8 for ß-HCG levels at days 4 and 7 respectively, 4.02 and 2.47 for decrement between days 0–7 (25%) and 4–7 (20%), respectively.Conclusion: ß-hCG cutoff values have a potential for predicting a successful medical treatment of TEP.