Abstract
The aim of the research was to assess using biodegradable screws in treatment of hallux valgus. We managed 40female patients (average age 50±2.51) with hallux valgus who where admitted to the orthopedic unit of Irkutsk Scientific Center of Surgery and Traumatology for operative treatment.All patients had X-ray, MRI and intraoperational examination of affected foot before the surgery and in postoperative period. All patients were operated using own surgical technique.Patients were divided into two groups: group1 (22patients) – osteosynthesis using biodegradable (PLGA) screws; group2 (18patients) – osteosynthesis using metal cannulated screws.In group1 postoperative values of M1P1 angle were within normal range (9.67±0.78°). According to MRI, proximal articular set angle (PASA) was corrected from 21.5±0.35 to 4.17±0.09°. 6patients of the group1 were complaining of pain and discomfort in the area of screw-head contacting soft tissues. The result of operative treatment in the group2 resulted in the correction of M1P1 angle from 34±1.63 to 7.67±0.75°. After the surgery intraoperative PASA was back to the normal range (4.33±0.34°).The comparison of the results of treatment of patients of groups1 and 2 didn’t reveal any statistically significant dif-ferences in the values of М1Р1, М1М2, М1М5 angles and PASA.The advantage of using biodegradable screws, compared to the metal ones, in the treatment of hallux valgus is the possibility of postoperative MRI of the foot with calculation of PASA to evaluate treatment results. The disadvantage of using biodegradable screws is engineering deficiency preventing screw-head from dipping into bone tissue and causing soft tissue traumatizing. Biodegradable and metal screws allow to obtain similar results of hallux valgus treatment.
Highlights
The aim of the research was to assess using biodegradable screws in treatment of hallux valgus
We managed 40 female patients with hallux valgus who where admitted to the orthopedic unit of Irkutsk Scientific Center of Surgery and Traumatology for operative treatment
Patients were divided into two groups: group 1 (22 patients) – osteosynthesis using biodegradable (PLGA) screws; group 2 (18 patients) – osteosynthesis using metal cannulated screws
Summary
На основании результатов лечения 40 пациентов с hallux valgus была дана оценка использования биодеградируемых винтов. Преимуществом применения биодергадируемых винтов, по сравнению с металлическими, является возможность выполнять после операции МРТ-исследование стопы с расчетом PASA. Недостатком является технический компонент, приводящий к недостаточному погружению шляпки винта в костную ткань и травматизации мягких тканей. Биодеградируемые и металлические винты позволяют получить аналогичные результаты лечения hallux valgus. Ключевые слова: вальгусное отклонение первого пальца стопы (hallux valgus), биодеградируемые винты, PLGA, PASA
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Бюллетень Восточно-Сибирского научного центра Сибирского отделения Российской академии медицинских наук
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.