The purpose of this study is to compare CT (disinfectant concentration * time) values in removing the antibiotic resistance bacteria, antibiotic resistance gene and transfer of antibiotic resistance genes. Different concentration of chlorine(C) and contact time(T) according to the removal of antibiotic resistance was calculated for each. As a result, for the 90% removal of antibiotic resistant bacteria, around 176~353 mg min/L CT values are needed. For the removal of the antibiotic resistance gene, 195~372 mg min/L CT values are required. For the 90% reduction of antibiotic resistance gene transfer by chlorine disinfection, 187~489 mg min/L CT values are needed. Based on our results, higher CT value was required for removing antibiotic resistant genes rather than antibiotic resistance bacteria.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.