Abstract

In this paper the authors showed the estimation process of the optimum number of the fixtures in a lavatory in the multi-purpose stadium. The authors estimated the optimum number of the fixtures in a lavatory using the data based on the data of past surveys, and verified the propriety of the estimation by the investigation of the real fixture usage conditions at the dome-N in Nagoya. Then following results were obtained. 1) The estimation process of the optimum number of the fixtures was proper. 2) The arrival rate of the spectators could be presumed by the data of past surveys. 3) The occupancy period could be estimated with Erlang distribution. 4) On the planning of the lavatories, it is necessary to consider the arrangement of the fixtures in addition to the optimum number of the fixtures

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.