Abstract

Large Cavitation Tunnel (LCT) of KRISO enables us to conduct cavitation tests of the propeller attached to a ship model. As the ship model tests are done at rather high Reynolds number of 107~108, flow measurement system such as pitot tube cannot be employed because of structural safety problems in its system and difficulties in installing it within the test section. Thus, KRISO has developed new 3-D LDV system used in large test section of LCT. There are several difficulties in using 3-D LDV, which did not allow efficient operation of it. The first trouble was the calibration using the conventional pin hole. To make the focus with same laser-beam waists at the wanted position, the high spatial resolution CCD is utilized in the calibration procedure for 3-D LDV. The off-axis configuration provides two velocity components in the horizontal plane and on-axis configuration gives third velocity component in the vertical plane. The horizontal velocity components are also obtained in the coincidence mode, which prevents any misleading results in the off-axis configuration. The nominal wake of Aframax tanker model is measured by the developed 3-D LDV system. The measured hull wake showed good agreement with that obtained by CFD calculation.