Abstract
Introduction The SuperPulse Thulium (Tm) fiber laser (wavelength of 1.94 m) has been recently introduced as a directed-energy source for urology. Preclinical studies have shown a significant potential of the SuperPulse Tm fiber laser (SP TFL) for lithotripsy. However, clinical reports of using SP TFL to treat urolithiasis are still few and limited. Of special interest are challenging cases, e.g., lower pole stones, when extreme deflection of the instrument is required. Objective To evaluate the effectiveness of the SuperPulse Tm fiber laser in the management of lower pole small calyceal stones during flexible ureteroscopy (F-URS). Method s. The SuperPulse Tm fiber laser device (Urolase 2, IRE Polus, Fryazino, Russia) has been cleared for clinical use by the Ministry of Health of Russian Federation. Study protocol has been approved by the Ethical Review Committee. Between January 2018 and February 2019, 130 patients with kidney stones have undergone Thulium fiber laser lithotripsy during F-URS. We retrospectively analyzed 15 of this patients with a single radiopaque lower pole calculus that were included in the present study. Stone size, stone density, lithotripsy time (from the first to last footswitch press) and lasering (laser emission) time were measured. The SP TFL was used for stone disintegration with different settings in dusting and fragmentation modes (0.1 - 4J, 7-300Hz, 6-40W) via a fiber with a 200-m core diameter. Low dose CT scanning was performed on POD 90 to assess SFR. Results Stone size ranged from 4 to 17 mm and stone density varied from 350 to 1459 HU. The average lithotripsy time was 12 min (3-30 min). The average lasering time was 1.3 min (0.4-2.5 min) and the mean hospital stay was 1.1+/-0.3 days. In all cases we reached the lower pole stone containing calyx with a laser fiber. The complication rates were evaluated by using the Clavien-Dindo grading system and did not exceed GII (6.6%). SFR on POD 90 was achieved in 86.6% of cases. Conclusions F-URS with SuperPulse Tm fiber laser is safe and effective option in the management of lower pole small calyceal stones. The possibility of using small laser fibers gives better instrument deflection which make possible to reach lower pole calyceal stones even with acute lower pole infundibulopelvic angle (IPA).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.