Abstract
The deflection behavior of rigidly jointed single-layer latticed domes with several triangular networks subjected to a vertical concentrated load and/or uniform pressure have been studied experimentally. On comparing of the experimental results with calculated ones of finite element method, close agreements between them were obtained. The results indicate that the dome tends to buckle more easily as the distributed load increases and that the buckling characteristics depend on the Shell-likeness Factor S. In applying a concentrated load to the apex of the dome, the deflection characteristics standardize those for the other junctions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Structural and Construction Engineering (Transactions of AIJ)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.