Abstract

We report the radiation exposure dose received by the anesthesiologist and nurse in the orthopaedic operating room, when a fluoroscopic image intensifier is in use. This study was done in 12 femoral neck fracture operations performed from January to May 1995. Radiation was monitored with the MYDOSE MINIX PDM 107 made by Aloka Co. which were attached in front and behind the nurse's lead apron, in front of the lead apron of the anesthesiologist. The average imaging time was 9.78min. The average radiation dose in front of the anesthesiologist is lead apron was 2.08μ SV, and in front and behind the nurse's lead apron were 5.67μ SV, 0.08μ SV respectively. This study and review of the literature indicate that the operating room anesthesiologist and nurse receive a lower exposure than the orthopaedist. We can disregard the problem of radiation exposure to the anesthesiologist and nurse during an orthopaedic operation when they wear lead aprons and stand far from the patient.