We have been perfoming Bateman prosthesis replacement for the osteoarthritis of the hip joint since 1980. In the present study, 13 cases with 15 joints were examined directly, and 4 cases with 5 joints were examined by questionnaire after follow-up of more than 5 years post-operative course.The age range was from 43 to 75 with an average of 55.4 years.13 cases with 15 joints were evaluated by roentgenograms.The clinical results showed that preoperative total average score of 47.7 points was improved to 80.2 points postoperatively by Japanese Orthopedic Association Hip Score System. Roentgenographic results showed that central migration stopped in 10 cases, loosening and sinking of the prosthesis occurred in no case, clear zone around the prosthesis occurred in 10 cases, and ectopic bone formation occurred in 3 cases postoperatively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.