Abstract

Desalination is one of the electrochemical methods, aiming to remove chlorides from reinforced concrete structures. However, it is impossible to extract all of chlorides contained in concrete. For this reason, it is important to improve the chloride removal efficiency and to estimate the durability of structures after treatment.In this study, distribution of Cl- (total chlorides and water soluble chlorides) was examined after applying desalination. The effect of discontinuous treatment was also investigated. Secondly, change of half cell potential and polarization resistance with time were measured after desalination.The results showed that the steel protection effect due to applying desalination had been maintained for long time. However, in this study, it was difficult to improve chloride removal efficiency by means of intermittent treatment. So, measuring of half cell potential and polarization resistance is useful to monitor the steel condition after treatment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.