Abstract

Surface acoustic wave(SAW) device is used for transporting and patterning micro-scale particles such as cells. In this research, velocity of particles was investigated moved by SAW device with two types of interdigital electrode transducers(IDTs) under various conditions. SAW devices which have single IDTs and double IDTs were designed and fabricated. On the previous studies, resultant velocities of particles were predicted considering output power and power ratio between IDTs-shape. For more accurate prediction, power loss in SAW device and a power difference between two types of IDTs-shape were considered. Maximum error between the test results and predicted values was 5 % so the power loss must be considered in the velocity prediction of the particles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.