Abstract

The paper presents results of research on radiological protection of the public during normal op-eration of Pilot-demonstration energy complex (PDEC) and in increased total power of reactor plants in the Industrial power complex (IPC) based on the current national radiation safety stand-ards (NRB-99/2009), UNSCEAR conclusions and ICRP recommendations. To evaluate radiologi-cal protection of the public the concepts of radiological detriment (RD) and the level of radiation protection (LRP) were used. The concepts were also used to examine the compliance of the BREST-OD-300, fabrication/refabrication module, processing module, BR-1200 and BN-1200 re-actors, collectively called nuclear objects, with safety standards. RD and LRP were estimated with the use of data of the Russian national cancer statistics and cancer statistics of the regions, wherein nuclear objects are planned to be placed – Tomsk, Sverdlovsk, Chelyabinsk. For the public residing nearby the nuclear objects the estimated LRP and RD meet NRB-99/2009 re-quirements concerning the restriction of radiation risk at the level of 10Е-5 from potential irradiation during a year. For the public of the critical group (girls younger than 5 years of age), residing nearby the PDEC and the nuclear objects the negligible risk of 10Е-6 can be achievable if annual radiation doses of 3H, for BREST-OD-300, reduce by 80%, and of annual doses of Cs-137, for the processing module reduce by 75%. The negligible risk for the public can be achieved if annual radiation doses of H-3 for BREST-OD-300 reduce by 10% and annual radiation doses of Cs-137 for processing module reduce by 5%. Projected radiation risk value for the public residing nearby BN-1200 and BR-1200 or nearby the IPC with two BR-1200 facilities will be much lower than the level of the negligible risk of 10Е-6. The RD calculated with ICRP methodology, serves as confirmation of the need to improve efficiency in cancer care in Tomsk region in order the regional RD to be at the national level. Because the high level of radiological protection of the public during the normal operation of the fabrication/refabrication module, its further operation when establishing IPC based on BR-1200 is feasible.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call