Abstract

Reactivity estimation using the neutron flux signal has been carried out mainly by two methods, inverse kinetics equation method and Kalman filtering method. Recently a new estimation method has been proposed. The method is based on the H∞ optimal estimation theory and can improve rather slow time response of the Kalman filtering method.The previous studies on these methods, however, have been reported independently. Hence, the information required to select the most suitable method seems to be insufficient, especially for those who plan to design a new reactivity meter. From this point of view, we carried out a comparison study on the important characteristics for reactivity measurement, noise filtering and time response, between H∞ estimator and the inverse kinetics equation method derived by neglecting the time derivative of neutron flux.The comparison results show that the two types of reactivity meters have similar characteristics. Also some findings are shown for the tunig guidance of a parameter(γ) which determines the characteristics of H∞ estimator to be designed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.