Abstract
The purpose of study is to clarify 1) the acceleration effect of SO2 gas on the generation of migration, and 2) the generation mechanism of migration under the SO2 gas environment. The experiments were carried out using the circuit board set in the cycle testing tank controlling temperature and humidity. The voltage applied to the test wirings was 50 V. SO2 gas concentrations were 0, 0.3, 12 and 85 ppm. Distances between wirings were 0.16, 0.4, 1, 2.5 and 6.3 mm. The one cycle of the cycle testing was first (5°C, 60%RH, 20 min.) and second (25°C, 90%RH, 20 min.). The results show that the progress of the migration in SO2 gas environment is accelerated by changing the water absorbed on the surface between wirings into acid water caused by SO2 gas and migration with wirings of 6.3 mm distance was observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.