Abstract

A digital void velocimeter with a single-type probe was developed that enables the measurement of void surface transit-time in a gas-liquid two-phase flow irrespective of void surface deformation. The accuracy of void velocity measurement by the conventional single-type probe technique is governed by the deformation of the void surface, and the error is within ±10% for the group of voids with almost identical curvatures.The present scheme was made possible by building a signal control circuit linked to a microcomputer. An on-line data processing system was also developed, and the error of the measurement was within ±6%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.